The HAV Rapid Test Cassette (Serum/Plasma) is a qualitative membrane-based immunoassay
for the detection of HAV antibodies in serum or plasma.This test consists of two components,an
IgG component and an Igm component In the lgG component,anti-human IgG is coated in lgG
test line region.During testing,the specimen reacts with anti-HAV antibody particles in the test Device.The mixture then migrates upward on the membrane chromatographically by capillary action and reacts with the anti-human IgG in IgG test line region. If the specimen contains IgG
antibodies to HAV,a colored line will appear in IgG test line region.
In the IgM component,anti-human IgM is coated in IgM test line region.During testing.The
specimen reacts with anti-human IgM HAV IgM antibodies,if present in the specimen, reacts with
the anti-human IgM and the anti-HAV antibody particles in the test Device,and this complex is
captured by the anti-human IgM,forming a colored line in IgM test line region therefore if the
specimen contains HAV lgG antibodies,a colored line will appear in log test line region.If the
specimen contains HAV IgM antibodies,a colored line will appear in IgM test line region. If the
specimen does not contain HAV antibodies,no colored line will appear in either of the test line
regions, indicating a negative result.To sever as a procedural control,a colored line will always appear in the control line region indicating that membrane wicking has occurred
| Availability: | |
|---|---|
| Quantity: | |
IHA-6013
Formaster
The HAV Rapid Test Cassette (Serum/Plasma) is a qualitative membrane-based immunoassay for the detection of HAV antibodies in serum or plasma.This test consists of two components,an IgG component and an Igm component In the lgG component,anti-human IgG is coated in lgG test line region.During testing,the specimen reacts with anti-HAV antibody particles in the test Device.The mixture then migrates upward on the membrane chromatographically by capillary action and reacts with the anti-human IgG in IgG test line region. If the specimen contains IgG antibodies to HAV,a colored line will appear in IgG test line region. In the IgM component,anti-human IgM is coated in IgM test line region.During testing.The specimen reacts with anti-human IgM HAV IgM antibodies,if present in the specimen, reacts with the anti-human IgM and the anti-HAV antibody particles in the test Device,and this complex is captured by the anti-human IgM,forming a colored line in IgM test line region therefore if the specimen contains HAV lgG antibodies,a colored line will appear in log test line region.If the specimen contains HAV IgM antibodies,a colored line will appear in IgM test line region. If the specimen does not contain HAV antibodies,no colored line will appear in either of the test line regions, indicating a negative result.To sever as a procedural control,a colored line will always appear in the control line region indicating that membrane wicking has occurred